Skip to content

WestPoint · Fire · Detnov

Spanish manufacturer. Not a flag: it's the phone call on a Tuesday.

Addressable control panels and detectors made here. What changes is not the electronics: it is how long it takes you to speak to somebody who knows the answer and how long a part takes to arrive.

What it is, and where you'll find it.

Detnov — Spanish manufacturer: control panels and detectors. A relatively young house with a focused range.

It makes addressable control panels and the devices that hang off them: optical, heat and dual-technology detectors, call points, sounders and input and output modules. The range is coherent and not endless, and that has a virtue: the installation is built with parts that are designed to work together and that are documented together.

It turns up in office buildings, medium-sized industry, schools, care homes, hotels, retail and new build in general. And it turns up quite a lot in installations where the client wants professional electronics but does not want the complexity —or the price— of a head end designed for an airport.

The manufacturer being here changes four very concrete things.

None of the four is patriotism. All four are logistics, and you notice them in the maintenance more than in the installation.

The first is the time zone. When something that does not add up shows up during commissioning, the difference between resolving it that morning and resolving it the day after tomorrow is that at the other end of the phone there is somebody working the same hours you are. It sounds minor until you are on a site with a delivery date.

The second is the documentation. Manuals, drawings and data sheets in Spanish, written for the regulatory framework that applies here. That is not comfort: the documentation is not read only by the installer, it is read by the client's maintenance manager and it is read by whoever comes to inspect. A manual half translated or in another language ends up meaning that nobody reads it.

The third is the spare part. A card, a power supply or a batch of detectors leaving a mainland warehouse arrive in days and with no customs. And the fourth, which is the one that counts most over time: the chain is short. When something odd has to be resolved, there are fewer intermediaries between the question and somebody who really knows the product from the inside.

What this does not mean: it does not mean it is a better panel than another, and we are not going to say that. It means the cost of living with it for fifteen years is lower and more predictable, and that is a legitimate buying criterion that almost never goes in the comparison table.

How it's built.

A modular panel that grows with loop cards, with its maximum number of devices and its maximum length per loop. The usual rule: those maximums are not used up on handover day, because in this country every building grows on the inside and a full loop forces a new card at the worst moment.

The sounder lines are supervised, which is what lets you find out that a cable is cut before the day it needs to sound. The batteries are calculated with the real consumption of the installation at rest and in alarm, and not with the catalogue figure, which is the most repeated sizing mistake in the trade. And there are free inputs and outputs for the interfaces with the rest of the building, which is where half the value of a fire system lives.

The configuration is done from PC software and what gets written there is the cause and effect matrix: what triggers what, with what delay, on which storeys and what stops. That file and its password belong to the client and are handed over. A panel only the person who fitted it can get into is not a maintainable panel.

What makes it reliable, and what makes it go off when it should not.

What makes it reliable is the self-monitoring, the same as any decent addressable system: it knows if a device is missing, if one is dirty, if there is an earth fault on a loop or if the battery no longer holds. And there is a function in these panels that is worth using and almost nobody uses: remote supervision of the installation, which lets you see those alerts without anybody having to walk past the cabinet. A fault alert nobody sees is the same as not having it.

It goes off when it shouldn't because of the wrongly chosen detector, like all of them. With one nuance that causes a lot of trouble in medium-sized industry: the dual-technology detector is sold as the answer for dirty places and it is not the answer for all of them. In a place with dust constantly in the air or with exhaust fumes, what is often called for is detecting heat and not smoke, even if that means detecting later. It is a design decision with a consequence that has to be explained to the client, not an adjustment made at commissioning.

Who it fits, and who it doesn't.

It fits where you want professional, addressable electronics, with a short support chain and without paying for complexity that is not going to be used. And it fits particularly well where the client knows they are going to have that installation for a long time and cares about the cost of living with it: spares, support, training, documentation.

It does not fit if the specification asks for governing a whole campus with dozens of panels, redundancy on the network and graphics on the plan in a control room, nor if a technical room has to be protected with aspirating detection or a tunnel with linear detection. Those needs exist and they have their product, which is in this same area. Forcing a mid-range family to do the work of an enterprise head end comes out expensive in configuration and in grief.

We are an electronics firm too.

The symmetry is funny and worth saying out loud: an electronics manufacturer and an electronics integrator. Neither of us does pipework.

What we do: detection, control panel, call points, sounders, evacuation, integration with the ventilation, the doors, the access control and the cameras, tests and maintenance of all of that.

What we do not: sprinklers, dry risers, fire hose reels, pump sets, tanks and any pipe with water inside it. It is another line of work, with another licence and another signature, and it is contracted separately. In gas fire suppression the border runs in the same place as in all of them: the detection and the release are ours, the cylinder bank and its pipework are not.

What we do with it.

  • The design first: what has to be detected in each place and with what, with the smoke or heat decision explained and its consequences said out loud. Loops shared out by sector and free capacity for what is coming.
  • The cause and effect matrix written out in words, agreed by whoever is in charge of the building and then tested line by line.
  • The remote supervision configured and, above all, with a named person who receives the fault alerts and knows what to do with them. Without that it is a function that is switched off.
  • The tests with a dated and signed certificate: every point, the complete sequence, the power cut and the transmission of the alert genuinely checked.
  • The handover: drawings of what is there, configuration file and passwords in the client's name, inspection schedule and training for the building's staff.

Who operates it once we leave.

The day-to-day, the client, and here with a real advantage: the documentation is in Spanish and can be left on the maintenance manager's desk without translating anything. Reading the panel, telling alarm from fault, silencing, resetting, isolating with a record and knowing what is not touched. Two hours of training and a one-page procedure.

The structural part, no: new devices, changes to the matrix, interfaces and updates. That belongs to whoever knows the installation, because done halfway it leaves the system switched on and lying.

And the maintenance with its schedule and its file, which costs money every year. We say it on every page because it is the part that falls out of quotations most often and the only one that makes sure that in five years the system is still the one that was handed over.

What gets decided in the detection project

Where to go next.

The brand of the panel matters less than which detector goes in each place and who answers for the tests. That is what the area is about, and it is worth reading before comparing prices.

Get started

New build, or an installation that has to be extended?

Tell us what building it is, how many points, what is already fitted and what is going to change in the next few years. We will tell you what panel makes sense, with which detector in each place and what it is going to cost to maintain each year, which is the number nobody puts in the quotation.